Thursday, September 5, 2024

depot skid lifting lug calculation

https://3d-labs.com/product/depot-skid-lifting-lug-calculation/ 

This calculation the design requirement of lifting lug we going to considered the weight of the 

component to be lifted is 50000 kg , impact factor Nd is 2 ,component force acting  on the beam

F is 981000 Number of lug eye is 4,maximum combined force acting on lug eye Fc is 245250N.



davit design calculation

https://3d-labs.com/product/davit-calculation-design/ 

A davit is used to secure the blind flange

and keep it from falling , especially in heavyweights

more than 25 kg. The blind flange has two handles for

opening purposes (Fig. 16.45). The davit is integrated into

the blind flange from one side and bolted with two nuts.

The davit base is generally a permanent structural fixture

on the roof of the building. It serves as the primary

anchor point that provides support to the mast, arm,

and the suspended platform that hooks over the

edge of the building.



calculation of transport saddle design

https://3d-labs.com/product/calculation-of-transport-saddle-design/ 

calculation of transport saddle design,download calculation

of transport saddle design, transport saddle design.

Transport saddle design involves calculating load capacity, selecting suitable

 materials, determining geometry, conducting structural analysis, applying safety

 factors, designing secure attachment points, considering fatigue resistance, specifying 

surface treatments, ensuring manufacturability, and validating the design through testing.



calculation of tailing lug design

https://3d-labs.com/product/calculation-of-tailing-lug-design/ 

In this calculation the design requirement of lifting or tailing lugs provide lifting lug size, forces,

and also how much amount of shear stress occurs during lifting the Lug. The lifting lug Material

is SA 516 Gr.70. the allowable yield, shear, bending, tensile and weld stresses are considered this

calculation. And also, total weight of the equipment, safety factor number of lugs to provide,

design load of one tailing lugs, and maximum horizontal, vertical loads to be considered during

the calculations. Since all the induced stress is less then allowable stress hence the design is safe. 

So We provide the detailed calculations of lugs to lift entire vessel/tank.



calculation of api 653 tank shell evaluation

https://3d-labs.com/product/calculation-of-api-653-tank-shell-evaluation/ 

Calculation of API 653 Tank Shell Evaluation” involves rigorous assessments following

the American Petroleum Institute’s standards. Engineers analyze factors like corrosion rates, 

shell thickness, material properties, and environmental conditions to ensure tank shell integrity.

Utilizing methods such as ultrasonic testing and visual inspection, these calculations identify

structural risks early, guiding maintenance and repair strategies. Compliance with API 653 

standards ensures regulatory adherence and the reliability of storage facilities.



calculation of anchors-cross section

https://3d-labs.com/product/calculation-of-anchors-cross-section/ 

 Calculation of Anchors-cross section

 The function of anchor bolts is to transfer loads to

  the masonry from attachments such as ledgers , sills, and bearing plates. Both shear and

  tension is transferred through anchor bolts to

  resist design forces such as uplift due to wind at the top of a column or wall or vertical

  gravity loads on ledgers supporting joists or trusses.



asic bolting design calculation

https://3d-labs.com/product/aisc-bolting-design-calculation/ 

 Required tightening moment - determined by the prestress force and affected by

 the friction factor in threads between the nut and bolt , and by the friction factor

 in the contact surface of the nut or bolt. Bolt value is the strength of the bolt.

 The strength of the bolt is taken as the minimum value of the following.

 (Shearing strength in a bolt. Bearing strength in a bolt. Tensile strength in a bolt.)

 The shear strength of all bolts = shear strength of one bolt x number of bolts

 The bearing strength of connecting/connected plates can be calculated using

 equations given by AISC specifications.



glstank -awwa d103 design

https://3d-labs.com/bolted-storage-tank/   Glass Fused to steel / Glass -lined  steel technology,  is a leading solution which combines the ...